Double Sided LED Sign Installation on Wall
1) Project Summary
Install a double-sided corner-mounted LED sign upgrade, with two 3' × 23' single-sided LED displays arranged in a V-shape meeting at the corner of the building, alongside two non-illuminated static signs. The new signs replace the existing outdated corner displays while maintaining the same position for maximum visibility from the freeway in both directions.

2) LED Sign Dimensions
Front view of 3' × 23' LED sign (per wall)

Rear view of LED sign

Side view of LED sign

Sign-side mounting brackets
Mounting brackets are provided to attach the LED sign display to the wall frame.

| LED Sign Display Dimensions: | 3.1 feet × 24.2 feet |
| Power Requirements: | 59.6 AMPS @ 110V or 29.8 AMPS @ 220V / Side |
| Weight: | 690 lbs / side |
3) Bid Required
Please submit an itemized bid covering the complete scope below.
- Remove the existing sign
- Light assembly of the LED sign using X-brackets
- Fabricate the frame for the wall
- Fabricate the frame for the sign and mount the sign to the frame
- Mount the LED sign to the frame on the wall
- Fabricate and install perforated metal perimeter covers for the LED sign
- Process the permit
- Perform the pre-permit survey
- Electrical (optional line item): Final termination and connection at the existing electrical/junction box only — no trenching, no new circuits or feeders
- Terms and conditions apply
Not included in scope:
- LED sign and static sign supply
- Software programming and support
4) Bid Submission
- Email: projects@ledsigncity.com
- Subject line: Bid – Wall Sign Installation – Centennial, CO
5) Site Map & Location Reference
Installation Location
6860 S Yosemite Ct
Centennial, CO 80112

Existing Site Condition

Proposed Rendering — Side 1

Proposed Rendering — Side 2

Rendered View — One Side

Rendered View — Other Side

Vantage View

6) Wiring Specifications: How to Connect the Sign
Electrical Recommendations
- 4 circuits of 20 amps per side, for a total of 8 circuits for the double-sided sign. Circuits must not be shared and must not be on a timer.
- An indoor disconnect switch is recommended to allow power to be safely cut in the event of an emergency or extreme weather.
- The power connection point should be within 5 feet of the sign to accommodate the sign's onboard cables. Running power to that point — whether from a breaker panel, conduit, or junction box — is outside the scope of installation and should be handled by a licensed electrician.